- Home
- ยป
- Business Segments
- »
- Bio safety Cabinet
Bio safety Cabinet
Bio Safety Cabinet Manufacturer
Minimum Order Quantity: 1 Piece
Cabinet Material | Stainless Steel, Mild Steel |
Main Filter | HEPA Filter |
Sterilization | UV Germicidal Tube |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Certification | IQ ,OQ , PQ, DQ |
Condition | New |
Model Number | RI03 |
Product Type | BIO SAFETY |
Voltage (V) | 230 |
Airflow Velocity (m per s) | 90 FPM |
Airflow System | MEGNELIK GEUJ |
Vibration Level | 0.5 |
Type | VERTICAL |
Lighting Type | LED |
Color | WIGHT |
Brand | ROMBAI |
Size | 2 X 2 ,3 X 2 , 4 X 2 , 6 X 2 |
Inflow Velocity | 90 FPM |
Downflow Velocity | 90 FPM |
Particle Retention | 0.3 |
Caster | YES |
Constructions | MILD STEEL |
Fluorescent Lamp | 1 NOG |
General Use | FOR LAB |
Height | 2300 |
Heigth | 610 |
No Of Hepa Filter | 2 |
Width | 1300 IN MM |
- Specifications:
- Supply Voltage(V): 220V 50Hz
- Cleanliness: 100 grade@≥0.5μm (FBI209E )
- Number of colony: ≤0.5/utensil.time(Φ90mm cultivation utensil)
- Average wind speed: 0.3-0.6M/S(Adjustable)
- Noise: ≤62αB(A)
Additional Information:
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: MUMBAI
- Production Capacity: 5
- Delivery Time: 4 WEEK
Biological Safety Cabinets
Minimum Order Quantity: 1 Piece
Cabinet Material | Stainless Steel, Mild Steel |
Main Filter | HEPA Filter |
Sterilization | UV Germicidal Tube |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Certification | IQ ,OQ , PQ, DQ |
Condition | New |
Model Number | 9833187604 |
Product Type | BIO SAFETY |
Voltage (V) | 1000 |
Airflow Velocity (m per s) | 100 FPM |
Airflow System | MENELIK GEUJ |
Type | VERTICAL |
Color | WIGHT |
Brand | ROMBAI |
Size | 2 X 2 ,3 X 2 , 4 X 2 , 6 X 2 |
Inflow Velocity | 100 FPM |
Downflow Velocity | 90 FPM |
Particle Retention | 0.3 |
Velocity | 90 FPM |
Constructions | MILD STEEL |
Fluorescent Lamp | 1 NOG |
General Use | FOR LAB |
Height | 2300 |
No Of Hepa Filter | 2 |
Width | 1300 IN MM |
Working area size | 2 X 2, 3 X 2, 4 X 2 with shutter opening of 600 mm |
- Particle Retention: 0.12 / 0.3 micron above
- Cleanliness level of Classification: Overall better than Class 100 Of US FS 209 E or Class 5 of ISO 14644-1
- Material: Electro-Galvanized iron, IS 304 / 316 Grade SS
Product Details:
Class | Mean inflow velocity to achieve operator protection | Mean down flow velocity to achieve product protection |
I | > 0.7 m/s – 1.0 m/s | Not Applicable |
II | ≥ 0.4 m/s | 0.25 m/s – 0.50 m/sec |
III | ≥ 0.7 m/s with one glove removed | Not Applicable |
Bio Safety Cabinet
Minimum Order Quantity: 1 Piece
Cabinet Material | Mild Steel |
Main Filter | HEPA Filter |
Electric Supply | 230 V |
Noise Level | Less than 65 db |
Working area size | 2 X 2, 3 X 2, 4 X 2 with shutter opening of 489 mm |
- Supply Voltage(V): 220V 50Hz
- Cleanliness: 100 grade@≥0.5μm (FBI209E )
- Number of colony: ≤0.5/utensil.time(Φ90mm cultivation utensil)
- Average wind speed: 0.3-0.6M/S(Adjustable)
- Noise: ≤62αB(A)
Bio Safety Cabinet
Minimum Order Quantity: 1 Piece
Main Filter | HEPA Filter |
Noise Level | Less than 65 db |
Working area size | Approximately 2 X 2, 3 X 2, 4 X 2 with shutter opening of 489 mm |
Specifications:
• The main body should be mad in mild steel (Heavy gauge- 19 G)
• Table top and working zone should be made of stainless steel (304 grade)- Heavy gauge- 20 G
• Table top should be in two parts: Front perforated portion 5” in size, Non-perforated working zone, Work Area should be approximately 2 X 2, 3 X 2, 4 X 2 with shutter opening of 489 mm
• Air Flow should be vertical down low with 70 % Circulation 30 % exhaust
• Cleanliness level should be less than 3.5 particles/ liter of 0.5 mm and larger
• Noise Level should be less than 65 dB
• Vibration level: Less than 2.3 mm
• Average air ow should be 90±20 fpm
• Door fully automatic
• HEPA filters should be Mini Plate with 99.99% efficiency for 0.3 microns with integral metal guards & filter frame gaskets and manufactured in class 1000 super clean air conditioned Air pressurization system should be statically and dynamically balanced, environment for longer life.
• Fitted with special vibration reducing the system to suit low noise and vibrations. UV lamp should be in working zone (40 microwatts/ square cm at 254 mm or better) and placed so that the operator cannot see directly i.e. eyes should be always protected. Should have Rehabitable pre-filters should have the efficiency of more than 80%. Should have Switches & Electrical sockets outlets for 15/5 amp. Should have Pressure Monitors like Magnehelic gauge are required to indicate pressure drop air. Exhaust blower should be capable for 100% exhaust interconnected with supply air blower; the system should only start when the negative pressure is developed Back holes should be there on vertical walls to provide more work area on Should have Switches & Electrical sockets outlets for 16 amp. Suitable power supply 230 volts a/c
Additional Information:
- Item Code: Class-2-A2